Set the
Grid Free.

Free from fire risk · Free from SF6

Dry-Type and Clean Air technologies eliminate the critical dependency that has defined – and constrained – high-voltage infrastructure for decades.
The result: safer infrastructure, simpler installations and a grid built for what comes next.

Dry-Type and Clean Air units installed worldwide
0 k+
Maximum voltage capability
Up to 0 kV
Countries with Trench Dry-Type and Clean Air installations
0 +

A Fact-Based Comparison.
Solution by Solution.

Across Bushings, Shunt Reactors, and Instrument Transformers, our oil-free and SF6-free technologies consistently lead where it matters most: safety, maintenance, and lifetime performance.

The comparison below shows exactly where Dry-Type and Clean Air solutions outperform oil-filled alternatives – and, with the same transparency, the areas where oil-filled retains a specific advantage.

Characteristic Dry Bushings Oil Bushings
No oil leakage
Maintenance
Fire risk mitigation
Explosion risk mitigation
Lower economical impact
Lifetime

No oil leakage

Dry Bushings
Oil Bushings

Maintenance

Dry Bushings
Oil Bushings

Fire risk mitigation

Dry Bushings
Oil Bushings

Explosion risk mitigation

Dry Bushings
Oil Bushings

Lower economical impact

Dry Bushings
Oil Bushings

Lifetime

Dry Bushings
Oil Bushings
Characteristic Dry Shunt Reactors Oil Shunt Reactors
No oil leakage
Maintenance
Fire risk mitigation
Explosion risk mitigation
Reduced total cost of ownership
Modularity
Smaller footprint
Variable option

No oil leakage

Dry Shunt Reactors
Oil Shunt Reactors

Maintenance

Dry Shunt Reactors
Oil Shunt Reactors

Fire risk mitigation

Dry Shunt Reactors
Oil Shunt Reactors

Explosion risk mitigation

Dry Shunt Reactors
Oil Shunt Reactors

Reduced total cost of ownership

Dry Shunt Reactors
Oil Shunt Reactors

Modularity

Dry Shunt Reactors
Oil Shunt Reactors

Smaller footprint

Dry Shunt Reactors
Oil Shunt Reactors

Variable option

Dry Shunt Reactors
Oil Shunt Reactors
Characteristic Clean Air ITs Oil ITs
No oil leakage
Maintenance
Fire risk mitigation
Explosion risk mitigation
Lower economical impact
No pressurized unit
Smaller dimension
Lifetime

No oil leakage

Clean Air ITs
Oil ITs

Maintenance

Clean Air ITs
Oil ITs

Fire risk mitigation

Clean Air ITs
Oil ITs

Explosion risk mitigation

Clean Air ITs
Oil ITs

Lower economical impact

Clean Air ITs
Oil ITs

No pressurized unit

Clean Air ITs
Oil ITs

Smaller dimension

Clean Air ITs
Oil ITs

Lifetime

Clean Air ITs
Oil ITs

The Grid Needs
Better Technology.

Dry-Type bushings, Dry-Type air core reactors, and Clean Air instrument transformers eliminate the need for containment bunds, fire suppression systems, oil monitoring circuits and SF6 management.

Simpler to build. Safer to operate. Easier to maintain.
The infrastructure of the future doesn’t carry the liabilities of the past.

Built with Superior Technology.
Engineered Without Limits.

Every product in the Trench Dry-Type and Clean Air range is engineered without oil, without SF6 and without compromise – from high-voltage bushings to air core reactors rated up to 765 kV for the most demanding grid applications.

Bushings — RIS · Resin Impregnated Synthetic (up to 580 kV)

RIS Transformer Bushing
Resin Impregnated Synthetic · Up to 580 kV

Bushings — RIG · Resin Impregnated Glass Fiber (up to 52 kV)

RIG Generator Bushing
Resin Impregnated Glass Fiber · Up to 52 kV
RIG High Current Transformer Bushing
Resin Impregnated Glass Fiber · Up to 52 kV

Bushings — RIP · Resin Impregnated Paper (standard & HVDC)

RIP Transformer Bushing
Resin Impregnated Paper · Standard
RIP High Current Transformer Bushing
Resin Impregnated Paper
RIP Wall Bushing
Standard · HVDC
RIP GIS Bushing
Gas Insulated Switchgear
RIP Transformer Bushing for HVDC
High Voltage DC
RIP Wall Bushing for HVDC
High Voltage DC
RIP Generator Bushing
High current applications
Air Core Shunt Reactors
Grid compensation
Air Core Series Reactors
Current limitation
ACR for Power Quality & FACTS
Power quality solutions
ACR for HVDC
High Voltage DC systems
Line Traps
Power line carrier

Clean Air Current Transformers

Clean Air Insulation · Up to 420 kV

Clean Air Inductive Voltage Transformers

Clean Air Insulation · Up to 420 kV

Clean Air Combined Transformers

Clean Air Insulation · Up to 420 kV

Clean Air Station Service Voltage Transformers

Clean Air Insulation · Up to 420 kV

Clean Air Gis
Current Transformers

Clean Air Insulation · Up to 420 kV

Clean Air Gis Inductive
Voltage Transformers

Clean Air Insulation · Up to 420 kV

The Right Technology Deserves the Right Conversation.

You’ve seen the case for Dry-Type and Clean Air.
Now let’s talk about your specific application.
Whether you’re evaluating a new project, comparing technologies, or ready to move forward – our team is here to help you make the right call.